Simplicity – Low Cost – Flexibility

The shelters series “501” are ideally suited for construction sites, construction camps and drilling camps, where they will be advantageously turned into offices, living accommodations, changing rooms and toilet facilities: all in all, the ultimate compromise between quality and price. The shelters series “501” can be stacked to form a two-storey high structure at the most, or linked lengthwise (short and/or long side) to form various complexes in line with the customer’s wishes. The key feature of the shelters series “501” lies in the fact that the structure is entirely seamless and secured by mere fitting bolting; as a result, they can be delivered completely disassembled (basement and roof included) in order to be loaded onto shipping containers. The great simplicity of the system and the reduced weight of each component make it possible, firstly, to assemble rapidly the structure without using mechanical handling equipment, secondly, to have the building knocked down, shipped and relocated; this is an easy and low-cost operation. If need be, the shelters series “501” can be delivered fully assembled and duly provided with all necessary fittings, cables and pipes, ready to be connected to the mains on site.

DIMENSIONS

Length:  1,83 – 2,83 – 3,83 – 4,83 – 5,83 – 9,29 m
Width: 2,4 – 2,89 m
Outside height: 2,65 – 2,95 m
Inside height: 2,4 – 2,7 m

Other dimensions can be arranged to meet specific requirements expressed by the Customer.
 

Basement

The basement is self-supporting and consists of an edge frame , galvanised steel C-channels, bolted to the four corner blocks.
The result is a durable and highly rigid structure upon which the floor stands.

Floor

Step floor is made in recycled plastic extruded panels.The Panels are waterproof, anti-bacterial, anti-mushrooms and anti-insects, fixed to the sub-structure by drywall nails and covered by wall to wall.
Floor live load: 250 Kg/m2 uniformly distributed.

External Walls

External walls consist of self-supporting sandwich type panels.
The insulation is ensured either by a core of self-extinguishing polyurethane resins, or by strips of mineral wool. In this case, upon request, the panels can be supplied with REI certification according to UNI EN 13501.
Panels have waterproof and dustproof tongue-and-groove vertical joints and are fully interchangeable.
Finishing between walls and floor is achieved by baseboard in PVC.
Finishing between wall panels at corners is implemented with flashings in pre-coated steel sheet fixed by screws or rivets.

Roof

The roof consists of a galvanised pre-coated section which runs along the outermost parts of the shelter and can accommodate both cover and wall panels.
The roof is constructed from self-supporting sandwich-type panels with a pre-coated galvanised ribbed outer metal sheet and pre-coated galvanised ridged inner metal sheet.
Standard roof strength: 150 Kg/m2 uniformly distributed.

Upon request, a second roof covering constructed.

Internal Partition Walls

Internal partition walls consist of self-supporting sandwich type panels. The insulation is ensured either by a core of self-extinguishing polyurethane resins, or by strips of mineral wool. In this case, upon request, the panels can be supplied with REI certification according to UNI EN 13501. Panels have waterproof and dustproof tongue-and-groove vertical joints and are fully interchangeable.

Doors and Windows

Doors and window frames, made from silver anodised aluminium-based alloy profiles, are assembled  on a galvanized, prepainted steel frame. Standard windows are of the outward protruding type; they are supplied with Termopan 4/10/4 glass, inner handles and extendable/retractable arms that lock the sash once open.
The number of windows and their dimensions are such as to ensure a 1/8 ventilation/lighting ratio. Fittings available upon request .
External solid doors made from a polystyrene insulation board.
Fittings available upon request include: anti-panic bars, upper/lower safety glass, door closers.
Internal doors are formed by the doors are made in white insulated aluminum panel.
Other doors and windows types can be supplied on specific requirements expressed by the Customer.

Electrical Installation

In accordance with currently enforceable regulations.

A waterproof junction box is mounted on the outside of the building, while the inside houses a self-extinguishing PVC electric panel.
10A/16A shuttered socket outlets, widely used in the country of application, are positioned in a manner such as to match the various installed appliances.
According to its intended use, indoor lighting inside each building can be achieved either by means of glass fibre reinforced polyester ceiling fixtures and a methacrylate diffusing screen.

Sanitary Installation

Plumbing fixtures are engineered for time effectiveness and easy maintenance.
The supply ducts are of butylenes complete with fittings and fixtures for hot and cold water.
Sewage pipes are in polyethylene, securely fixed to modules and led to the designed exit point for connection to the external sewerage mains.

Heating and Air Conditioning Systems

The heating system, if any, consists of wall mount, electric convector heaters with temperature controller.  As to possible air conditioning, window type air conditioners or split air conditioners coming in cool-only versions or reversible heat pump configurations, are available.
Other heating and air conditioning sistems can be arranged to meet specific requirements expressed by the Customer.

Assembly Kit

5,3 m³

All components are packed so as to occupy approximately a 5 m3 volume.
Consequently, 6 self-contained packaged buildings at most can be loaded onto a shipping container 20 feet long.